Character:
Combi-functional, with intelligent shore and generator power management
Uninterrupted AC power (UPS function)
Virtually unlimited power thanks to parallel operation
Three phase capability
Power Control ¡V Dealing with limited generator, shore side or grid power
Power Assist ¡V Boosting the capacity of shore or generator power, an innovative feature of the CombiPlus
Four stage adaptive charger and dual bank battery charging
Energy Unlimited
Error message display
Programming auxiliary relay (x 3)
Programming input current limit for power share
Capacity expansion by max. 10 sets of solar chargers
Description:
Stackable Inverter ~
Pure Sine Wave Inverter with AC Charger and Solar Charger (Option) + one more design [stackable function].
You may parallel SI Series, according to your requirement.
One unit is about 1.5K, if you want to increase to 4.5K, you just need to parallel 3pcs SI Series.
Connect directly with Solar system.
Natural Power System, Energy recycle for solar, Future trend.
Specifications:
MODEL
|
RSO-150I-12 (12 Volt)
RSO-1500-24 (24 Volt)
RSO-1500-48 (48 Volt)
|
INVERTER
|
Input Voltage Range (VDC)
|
9.5~16VDC / 19~32VDC / 38~64VDC
|
Output Voltage (VAC)
|
90~120VAC / 185~240VAC
|
Output Frequency
|
50Hz / 60Hz ± 0.1%
|
Output Voltage
|
Pure sinewave
|
THD
|
< 5%
|
Power Factor
|
All loads
|
Switch-on Behavior
|
Nominal output voltage within 20 msec.
|
Cont. Output Power at 25°C(W) (cos£c=1.0)
|
1500W
|
Cont. Output Power at 40°C(W) (cos£c=1.0)
|
1200W
|
Maximum Power (W)
|
3000W
|
Maximum Efficiency (%)
|
88 / 90 / 92
|
Zero-load Power (W)
|
12W
|
CHARGER
|
Input Voltage Range (VAC)
|
100~125VAC / 200~250VAC
|
Input Frequency
|
45~55Hz / 55~65Hz
|
Power Factor
|
1
|
Charge Characteristic
|
4-stage adaptive
|
Maximum DC Voltage Ripple (Vrms)
|
< 1.25 V
|
Charge Voltage "Absorption" (VDC)
|
14.4V / 28.8V / 57.6V
|
Charge Voltage "Float" (VDC)
|
13.8V / 27.6V / 55.2V
|
Output Charge "Voltage" (VDC) Min.,Max.
|
8V, 16V / 11V, 32V / 22V, 64V
|
Charge Current House Battery (A)
|
20A / 40A / 70A
|
Charge Current Starter Battery (A)
|
4A
|
AC INPUT SWITCH
|
Protected by Thermal Circuit Breaker
|
16A
|
Switch-over Time Inverter to AC Input
|
0 msec.
|
Switch-over Time AC Input to Inverter
|
0 msec.
|
Detection Time AC Input Fault
|
4 msec. to 20 msec.
|
Trip Level Mains to Inverter
|
90VAC / 180VAC
|
Trip Level Inverter to Mains
|
94VAC / 187VAC
|
Min.- Max. Frequency Range (50Hz/60Hz)
|
45~55Hz or 55~65Hz
|